Implantable cardioverter defibrillator

Autonomic cardiovascular control and cardiac arrhythmia in two pregnant women with hypertrophic cardiomyopathy: Insights from ICD monitoring

In women with hypertrophic cardiomyopathy (HCM), pregnancy prompts major changes in hemodynamic and cardiac autonomic function that may precipitate heart failure (HF) or increase the risk of cardiac arrhythmia. We report the clinical follow-up of two patients with non-obstructive HCM implanted with a cardioverter defibrillator (ICD) allowing for continuous analysis of heart rate (HR), heart rate variability (HRV) and cardiac arrhythmia throughout the entire course of pregnancy.

Safety and efficacy of anti-tachycardia pacing in patients with hypertrophic cardiomyopathy implanted with an ICD

Background: In hypertrophic cardiomyopathy (HCM) patients implanted with an implantable cardioverter defibrillator (ICD), clinical outcomes of antitachycardia pacing (ATP) have been poorly explored. In a retrospective analysis of a cohort of consecutive HCM patients implanted with an ICD, we aimed to assess the efficacy, safety, and clinical value of ATP. Methods: The cohort of HCM patients implanted with a transvenous ICD and followed in our center was assessed for device intervention from implantation to last clinical follow-up.

Subcutaneous implantable cardioverter defibrillator in patients with arrhythmogenic right ventricular cardiomyopathy. results from an Italian multicenter registry

Background: Despite expanding indication of the subcutaneous implantable cardioverter defibrillator (S-ICD) in clinical practice, limited data exists on safety and efficacy of S-ICD in arrhythmogenic right ventricular cardiomyopathy (ARVC) patients. The aim of this multicenter study was to evaluate the safety and efficacy of S-ICD in ARVC patients. Methods: The study population included 44 consecutive patients with definite ARVC diagnosis according to the 2010 ITF criteria (57% male, mean age 37 ± 17 years [range 10–75 years]) who received an S-ICD.

Implantation technique and optimal subcutaneous defibrillator chest position: A PRAETORIAN score-based study

Aims The traditional technique for subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation involves three incisions and a subcutaneous pocket. Recently, a two-incision and intermuscular (IM) technique has been adopted. The PRAETORIAN score is a chest radiograph-based tool that predicts S-ICD conversion testing. We assessed whether the S-ICD implantation technique affects optimal position of the defibrillation system according to the PRAETORIAN score. Methods We analysed consecutive patients undergoing S-ICD implantation.