Comparison between antimicrobial-coated sutures and uncoated sutures for the prevention of surgical site infections in plastic surgery. A double blind control trial.
Abstract
OBJECTIVE: Surgical site infection (SSI) produces considerable morbidity and increases health care costs. One of its causes is microbial adherence to the surgical sutures surface. A strategy to avoid microbial colonization is the use of antimicrobial-impregnated sutures. Recently absorbable sutures treated with chlorhexidine (CHX) have been developed. Our study purpose was to compare CHX-coated and uncoated suture in elective plastic surgery.