thermogravimetric analysis

Thermochemical characterization of polybenzimidazole with and without nano-ZrO2 for ablative materials application

During the ballistic atmospheric re-entry, a space vehicle has to withstand huge thermo-mechanical solicitations because of its high velocity and the friction with the atmosphere. According to the kind of the re-entry mission, the heat fluxes can be very high (in the order of some MW m−2) ;thus, an adequate thermal protection system is mandatory in order to preserve the structure of the vehicle, the payload and, for manned mission, the crew. Carbon phenolic ablators have been chosen for several missions because they are able to dissipate the incident heat flux very efficiently.

Advances in thermoanalytical techniques: may aspirin interfere with ß-thalassemia diagnosis?

Thermogravimetry coupled with chemometrics has proved to be a rapid and cost-effective diagnostic tool for β-thalassemia screening. This model, consisting of Partial Least Square-Discriminant Analysis (PLS-DA), permitted the discrimination of thalassemic patients and healthy individuals, using thermogravimetric curves of blood samples. In this study, the impact of aspirin on the capability of the TGA/chemometric validated model to screen for thalassemia was investigated.

Update on thalassemia diagnosis: new insights and methods

A novel approach based on Thermogravimetric analysis followed by Chemometrics (TGA/Chemometrics) is provided for Thalassemia diagnosis and a comprehensive study consisting of the coupled approach TGA/Chemometrics, the Complete Blood Count (CBC) and Red Blood Cell (RBC) indices is developed and results are compared. A number of 128 subjects were involved in this study included 16 thalassemia intermedia transfusion-dependent (TI-TD) patients, 18 thalassemia intermedia non transfusion-dependent (TI-NTD) patients, and 14 thalassemia major β (TM-TD) patients.

New methods for thalassemia screening: TGA/chemometrics test is not influenced by the aging of blood samples

The coupling of Thermogravimetry (TG) in conjuction with chemometrics was investigated for the first time to evaluate the capabilities of this novel test to provide the screening of thalassemia in blood samples stored at 4 °C until 15 days. Healthy donors were considered as reference subjects and a typical thermal behaviour as a function of aging was estimated and compared to thermal behaviour of thalassemia subjects. Diagnosis of thalassemia was made at the Day-Hospital Thalassemia of S.