Thermal architecture for the QUBIC cryogenic receiver

04 Pubblicazione in atti di convegno
May A. J., Chapron C., Coppi G., D'Alessandro G., De Bernardis P., Masi S., Melhuish S., Piat M., Piccirillo L., Schillaci A., Thermeau J. -P., Ade P., Amico G., Auguste D., Aumont J., Banfi S., Barbarán G., Battaglia P., Battistelli E., Baù A., Bélier B., Bennett D., Bergé L., Bernard J. -Ph., Bersanelli M., Bigot-Sazy M. -A., Bleurvacq N., Bonaparte J., Bonis J., Bordier G., Bréelle E., Bunn E., Burke D., Buzi D., Buzzelli A., Cavaliere F., Chanial P., Charlassier R., Columbro F., Coppolecchia A., Couchot F., D'Agostino R., De Gasperis G., De Leo M., De Petris M., Di Donato A., Dumoulin L., Etchegoyen A., Fasciszewski A., Franceschet C., Gamboa Lerena M. M., García B., Garrido X., Gaspard M., Gault A., Gayer D., Gervasi M., Giard M., Giraud-Héraud Y., Gómez Berisso M., González M., Gradziel M., Grandsire L., Guerrard E., Hamilton J. -Ch., Harari D., Haynes V., Henrot-Versillé S., Hoang D. T., Incardona F., Jules E., Kaplan J., Korotkov A., Kristukat C., Lamagna L., Loucatos S., Louis T., Lowitz A., Lukovic V., Luterstein R., Maffei B., Marnieros S., Mattei A., Mcculloch M. A., Medina M. C., Mele L., Mennella A., Montier L., Mundo L. M., Murphy J. A., Murphy J. D., O'Sullivan C., Olivieri E., Paiella A., Pajot F., Passerini A., Pastoriza H., Pelosi A., Perbost C., Perdereau O., Pezzotta F., Piacentini F., Pisano G., Polenta G., Prêle D., Puddu R., Rambaud D., Ringegni P., Romero G. E., Salatino M., Scóccola C. G., Scully S., Spinelli S., Stolpovskiy M., Suarez F., Tartari A., Timbie P., Torchinsky S. A., Tristram M., Truongcanh V., Tucker C., Tucker G., Vanneste S., Viganó D., Vittorio N., Voisin F., Watson B., Wicek F., Zannoni M., Zullo A.

QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel4He sorption cooler and a double-stage3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.

© Università degli Studi di Roma "La Sapienza" - Piazzale Aldo Moro 5, 00185 Roma