Investigation of free seleno-amino acids in extra-virgin olive oil by mixed mode solid phase extraction cleanup and enantioselective hydrophilic interaction liquid chromatography-tandem mass spectrometry

01 Pubblicazione su rivista
Piovesana Susy, Montone Carmela Maria, Antonelli Michela, Cavaliere Chiara, La Barbera Giorgia, Canepari Silvia, Samperi Roberto, Laganà Aldo, Capriotti Anna Laura
ISSN: 0308-8146

An analytical method for determining seleno-methionine (SeMet), methyl-seleno-cysteine and seleno-cystine in extra-virgin olive oil (EVOO) was developed and validated. EVOO sample (15 g) was diluted with hexane, extracted with methanol/water 80:20 (v/v), and cleaned up by a reversed phase/strong cation exchange solid phase extraction. Analysis was performed by chiral hydrophilic interaction liquid chromatography-tandem mass spectrometry. Process efficiency ranged between 49 and 97% and trueness between 87 and 126%, with intermediate precision, expressed as standard deviation, lower than 10%. Method detection limits (MDLs) and method quantification limits (MQLs) were lower than 1 μg kg −1 . Thirty-two EVOO samples from different Italian regions were analyzed for both total Se and single seleno-amino acids determination. Only L-SeMet was found at level MQL (0.2 μg kg −1 )-1.42 μg kg −1 in ten samples, while total Se was in the range of MDL-9.1 μg kg −1 . Concentration of L-SeMet (5–6% of total Se) and total Se correlated very well to each other (R 2 = 0.995). © 2018 Elsevier Ltd

© Università degli Studi di Roma "La Sapienza" - Piazzale Aldo Moro 5, 00185 Roma