Computed Tomography Angiography

CT texture-based radiomics analysis of carotid arteries identifies vulnerable patients: a preliminary outcome study

Purpose: To assess the potential role of computed tomography (CT) texture analysis (CTTA) in identifying vulnerable patients with carotid artery atherosclerosis. Methods: In this case-control pilot study, 12 patients with carotid atherosclerosis and a subsequent history of transient ischemic attack or stroke were age and sex matched with 12 control cases with asymptomatic carotid atherosclerosis (follow-up time 103.58 ± 9.2 months). CTTA was performed using a commercially available research software package (TexRAD) by an operator blinded to clinical data.

A double nellix and chimney covered stents: challenging treatment of pararenal aortic aneurysm

A 77-year-old male patient presented with a symptomatic, 66-mm pararenal aortic aneurysm. The patient was classified as unsuitable for open surgery due to significant comorbidities. Fenestrated or branched endografts were contraindicated due to the poor iliac access (6 mm diameter). A double Nellix with chimney endovascular aneurysm sealing (ChEVAS) technique was selected to exclude the pararenal aortic aneurysm and to preserve renal arteries and the superior mesenteric artery.

Optimizing contrast media injection protocols in computed tomography angiography at different tube voltages. Evaluation in a circulation phantom

OBJECTIVES:

The aim of this study was to investigate the minimum iodine delivery rate (IDR) and contrast media (CM) volume required for diagnostic contrast enhancement of 350 HU (Hounsfield units) in the ascending aorta at different kV settings.
METHODS:

Contrast media injection protocol optimization for dual-energy coronary CT angiography. results from a circulation phantom

Objectives: To investigate the minimum iodine delivery rate (IDR) required to achieve diagnostic coronary attenuation (300 HU) with dual-energy coronary CTA. Methods: Acquisitions were performed on a circulation phantom with a third- generation dual-source CT scanner. Contrast media was injected for a fixed time whilst IDRs varied from 1.0 to 0.3 gI/s in 0.1-gI/s intervals. Noise-optimized virtual monoenergetic imaging (VMI+) reconstructions from 40 to 90 keV in 5 keV increments were generated. Contrast-to-noise ratio (CNR) and coronary HU were measured for each injection.

Modified calcium subtraction in dual-energy CT angiography of the lower extremity runoff. impact on diagnostic accuracy for stenosis detection

Objectives: To investigate the diagnostic accuracy of a modified three-material decomposition calcium subtraction (CS) algorithm for the detection of arterial stenosis in dual-energy CT angiography (DE-CTA) of the lower extremity runoff compared to standard image reconstruction, using digital subtraction angiography (DSA) as the reference standard.

Spontaneous deep femoral artery false aneurysm simulating a neoplasm. A rare case and literature review

A 70-year-old woman presented to our attention with a painless pulsating mass at the level of the upper left thigh without any previous history of trauma, arterial surgery, or puncture of the femoral artery. Duplex ultrasound showed a nodular angiomatous-like formation with deep venous compression; computed tomographic angiography and magnetic resonance imaging reported the presence of capsulated lesion vascularized by muscular branch of deep femoral artery (DFA). The patient underwent surgical excision of a very rare thrombized DFA branch false aneurysm.

Unexpected Complication of a Nitinol-Constrained Balloon Angioplasty (Chocolate) in Rutherford Class 3 Patient Presenting Challenging Aorto-Iliac Anatomy

We report an unusual complication of Chocolate nitinol-constraining structure after right superficial femoral artery (SFA) angioplasty. The procedure was performed by vascular surgeons in an operating theater equipped by a portable fluoroscopy unit. Under local anesthesia, by a contralateral approach, a 7F introducer sheath was advanced through the proximal portion of the right common iliac artery. Owing to the severe aorto-iliac vessels calcification, it was not possible to place the introducer sheath into a more distal vessel, as planned.