EU DEMO

DEMO WCLL BB breeding zone cooling system design: analysis and discussion

The Water-Cooled Lithium-Lead (WCLL) Breeding Blanket (BB) is a key component in charge of ensuring Tritium self-sufficiency, shielding the Vacuum Vessel and removing the heat generated in the tokamak plasma. The last function is fulfilled by the First Wall (FW) and Breeding Zone (BZ) independent cooling systems. Several layouts of BZ coolant system have been investigated in the last years in order to identify a configuration that guarantee Eurofer temperature below the limit (823 K) and good thermal-hydraulic performances (i.e. water outlet temperature 601 K).

Thermal-hydraulic modeling and analyses of the water-cooled EU DEMO using RELAP5 system code

The conceptual design of the Primary Heat Transfer System (PHTS) of the water-cooled European (EU) DEMO foresees two independent cooling circuits, the breeding zone PHTS and the first wall PHTS. During the pulse time (120 minutes) the first delivers thermal power to the turbine, the latter delivers thermal power to the Intermediate Heat Transfer System (IHTS) equipped by an Energy Storage System (ESS).

© Università degli Studi di Roma "La Sapienza" - Piazzale Aldo Moro 5, 00185 Roma